Sizing flow valves is a science with many rules of thumb that few people agree on. In this article I'll try to define a more standard procedure for sizing a valve as well as helping to select the appropriate type of valve. **Please note that the correlation within this article are for turbulent flow. Step #1: Define the System The system is pumping water from one tank to another through a piping system with a total pressure drop of 150 psi.

The fluid is water at 70 テつーF. Design (maximum) flowrate of 150 gpm, operating flowrate of 110 gpm, and a minimum flowrate of 25 gpm. The pipe diameter is 3 inches. At 70 テつーF, water has a specific gravity of 1.0.

Jun 29, 2017. Pay attention mates! Here you can free download latest ACTIA Multi-Diag 2017 truck software! And also ACTIA Multi-Diag 2016 2015 previous versions. This works with original and clone ACTIA Multi Diag interface. It all depends on your interface serial number. Some serials are limited to certain versions. Jun 28, 2017. Here you can free download latest ACTIA Multi-Diag 2017 truck software! Added Original MDO adapters pinouts thanks to user Twist; Actia Multi-Diag III 2015 v.35.09+Service Pack 1 v.35.11+Service Pack 2 v.35.21; Actia Multi-Diag I 2016 v.36.05+Service. It all depends on your interface serial number. Keygen Actia Multidiag 2011 with serial number key activation, crack. Actia multi diag 2013. Serialkey preview: 8EB799B8. Added:; Downloaded: 80 times; Rating: 100%; Submitted by: anonymous; Full download: Actia_multi_diag_2013.rar. Please input captcha to take your serial number. Actia multi diag 2013 serial number. View in text. Actia multi diag keygen for mac.

Key Variables: Total pressure drop, design flow, operating flow, minimum flow, pipe diameter, specific gravity Step #2: Define a maximum allowable pressure drop for the valve When defining the allowable pressure drop across the valve, you should first investigate the pump. What is its maximum available head? Remember that the system pressure drop is limited by the pump.

Fisher Control Valve Sizing Software Firstvue Download Google

Essentially the Net Positive Suction Head Available (NPSHA) minus the Net Positive Suction Head Required (NPSHR) is the maximum available pressure drop for the valve to use and this must not be exceeded or another pump will be needed. It's important to remember the trade off, larger pressure drops increase the pumping cost (operating) and smaller pressure drops increase the valve cost because a larger valve is required (capital cost). The usual rule of thumb is that a valve should be designed to use 10-15% of the total pressure drop or 10 psi, whichever is greater. For our system, 10% of the total pressure drop is 15 psi which is what we'll use as our allowable pressure drop when the valve is wide open (the pump is our system is easily capable of the additional pressure drop). Step #3: Calculate the valve characteristic For our system: At this point, some people would be tempted to go to the valve charts or characteristic curves and select a valve. Don't make this mistake, instead, proceed to Step #4!

Hi, Chris I'm Emad Elgebesy. Senior process engineer in Worley Parsons. First of all, thanks for your clear efforts on the community, And im willing to share my experiance in this regard. In Worley Parsons, we did the valve calculation for, single phase & two phase. The above mentioned calculation did not demonstrate which phase is, But i think this liquid phase valve calculation only. After calculating the Cv, Supplier should verify the strock range (10% to 90%) is commnly used, noise level& body size as well.

Finally, there is many free control valve software of FirstVue do regirous calculation Regards Emad •. Chris, Nice article! I'd like to make a suggestion for a follow-up article. There are many times that we size liquid control valves in systems where the source pressure comes from a gas in the system instead of a pump (I am thinking of scrubber dump valves). Gpsmapedit 1.0.66.7 cracked. In these situations, after sizing the liquid valve, we often need to determine the 'gas blowby' rate, which is how much gas would flow through the valve if the liquid level control loop failed and left the valve wide open.